Description
XY-CD60L is a battery charge and discharge controller module. It can be used for
DC 6V~60V any one lithium/lead-acid battery.
Features
1>.Multi-function test instrument
2>.Dual mode work
3>.Support charging protection
4>.Support discharge protection
5>.Support set the charging/discharging time
6>.Automatic detection parameters
7>.HD LCD display
8>.Multi-parameter display
9>.Support power saving mode
10>.Supports automatic battery detection
Parameters
1>.Product name: XY-CD60L Lithium Battery Charging/Discharging Controller
2>.Model: XY-CD60L
3>.Work voltage:DC 6V-60V
4>.Work Temperature:-40℃~85℃
5>.Work Humidity:0%~95%RH
6>.Size:46*45*20mm
Function
1>.Module supports 2 working modes: Charging Control IN and Discharging Control
OUT.
2>.Charging Control IN: This mode is used for charging control to prevent
overcharging. Display symbol IN indicates charging mode.
3>.Discharging Control OUT: This mode is used for battery discharge control to
prevent battery over-discharge and delay battery life. Display symbol OUT
indicates discharging mode.
4>.Battery voltage percentage: It is value get from battery voltage V, Lower
Limit Voltage Value dn and Upper Limit Voltage Value UP. Calculation formula:
V/(UP-dn).
5>.Automatic parameter check: Screen will display and flashing ERR if the Lower
Limit Voltage Value dn is more than the Upper Limit Voltage Value UP.
Charging Control IN Mode
1>.Input terminal connect DC 6V-60V charger which use for battery.
2>.Output terminal connect 1pcs DC 6V-60V battery. It will display 0.00V and nbE
if the battery does not meet the requirements.
3>.Output turn ON and the input charger starts charging the battery if battery
voltage is less than the Lower Limit Voltage Value dn.
4>.Output turn OFF and the input charger stops charging the battery if battery
voltage is more than the Upper Limit Voltage Value UP.
5>.The symbol IN will flashing when charging.
Support set parameters
6.1>.Upper Limit Voltage Value UP: Maximum voltage of the battery. Stop charging
the battery if it exceeds this value. It is also the overcharge protection
voltage value.
6.2>.Lower Limit Voltage Value dn: Battery allowed minimum voltage. Start
charging the battery when the battery voltage is lower than this value.
6.3>.Charging Time OP
6.3.1>.Set battery charging time.
6.3.2>.Turn ON charging time control function when the OP parameter value is
more then 00:00. Minimum set time value 1minute.
6.3.3>.Turn OFF OP control if set 00:00.
6.3.4>.Start the timer when turn on output to start charging.
6.3.5>.Module turn OFF output to complete a charging process when timing is
completed.
6.3.6>.Module automatically turns OFF charging time control function if battery
voltage is less than the Lower Limit Voltage Value dn and flashing H:ER that
means the unreasonable time parameter setting. It means insufficient charging
and needs to continue charging the battery. Press any key to stop flashing.
6.3.7>.Record and display charging time if disabled Charging Time OP when short
press button SET. Clear time if at next charging or exit charging time display
interface.
6.4>.Turn ON Delay Time dOP: Set the delay interval between the first and the
second charging. The time range is 0~999second.
6.Discharging Control OUT Mode:
1>.Input terminal connect 1pcs DC 6V-60V battery.
2>.Output terminal connect suitable load. Note the output voltage is same to
battery.
3>.Output turn ON and the battery starts to discharging if battery voltage is
more than the Upper Limit Voltage Value UP.
4>.Output turn OFF and the battery stops to discharging if battery voltage is
less then the Lower Limit Voltage Value dn.
5>.The symbol OUT will flashing when discharging.
6>.Support set parameters
6.1>.Upper Limit Voltage Value UP: Threshold value to allow battery discharge.
6.2>.Lower Limit Voltage Value dn: Battery allowed minimum voltage. Stop
discharging when the battery voltage is lower than this value. It is also the
over-discharge protection voltage value.
6.3>.Discharging Time OP:
6.3.1>.Set battery discharging time.
6.3.2>.Turn ON discharging time control function when the OP parameter value is
more then 00:00. Minimum set time value 1minute.
6.3.3>.Turn OFF OP control if set 00:00.
6.3.4>.Start the timer when turn on output to start discharging.
6.3.5>.Module turn OFF output to complete a discharging process when timing is
completed.
6.3.6>.Module automatically turns OFF discharging time control function if
battery voltage is more than the Upper Limit Voltage Value UP and flashing H:ER
that means the unreasonable time parameter setting. Press any key to stop
flashing.
6.3.7>.Record and display discharging time if disabled Discharging Time OP when
short press button SET. Clear time if at next discharging or exit discharging
time display interface.
6.4>.Turn ON Delay Time dOP: Set the delay interval between the first and the
second discharging. The time range is 0~999second.
6.5>.Discharge Turn ON Forced Start Time FOP:
6.5.1>.This function is used to prevent the device from starting instantly and
reduce the battery voltage, so that it is lower than the Lower Limit Voltage
Value dn and causing the module to automatically turn off the output and causing
the battery can not discharge properly.
6.5.2>.The module will check the battery voltage again if enabled Discharge Turn
ON Forced Start Time function.
Button Description
1>.Long press means need keep press for more than 5second.
2>.UP button:
2.1>.Short press to switch display charging/discharging time and battery voltage
percentage.
2.2>.Long press to switch work mode. IN is Charging mode and OUT is Discharging
mode.
2.3>.Short/Long press to increase parameter value at parameter set mode.
3>.DOWN button:
3.1>.Short press to turn ON/OFF output.
3.2>.Long press to turn ON/OFF display status L-P (power saving mode):
3.2.1>.ON: Turn ON power saving mode. The display screen will turn OFF after
5~10minutes.Press any button to resume display.
3.2.2>.OFF: Turn OFF power saving mode. The display screen will keep ON all the
time.
3.3>.Short/Long press to decrease parameter value at parameter set mode.
4>.SET button:
4.1>.Short press to automatically switch/query display parameters UP/dn/OP/DOP
at charging mode and UP/dn/OP/DOP/FOP at discharging mode in normal display
interface. Short press to switch select parameter set in parameter set mode.
4.2>.Long press to enter into parameter set mode.
4.3>.Keep press about 5second to save parameter values.
Use steps
1>.Connect right input voltage at VIN+ and VIN-.
2>.Long press button SET to select work mode.
3>.Short press button SET to switch parameters.
4>.Short/Long press UP/DOWN to increase/decrease parameter value.
5>.Keep press about 5second to save parameter values.
6>.Remove input and connect load.
7>.Connect right input voltage at VIN+ and VIN- again.
Application
1>.Load tester
2>.Circuit tester
3>.Battery discharge tester
4>.Factory equipment inspection
5>.Ordinary load tester
6>.Power supply aging tester
7>.Auxiliary measurement charger Output current capability
8>.Charger Factory Batch Aging test use
Note
1>.Load terminal can not short circuit.
2>.It is a charging/discharging controller but not a charger!
3>.It can not be used as a charger!
4>.Please read use manual and description before use.
Frequency asked questions
1>.What is the control voltage range? What is the applicable battery range?
Q: Control voltage range is DC 6V-60V. But battery voltage max is 48V. Because
the voltage of 48V battery is 60V after fully charged.
2>.Why relay is automatically turned on and off continuously after power on and
flashing light?
Q: This is because your charging current is too large or the battery capacity is
too small that cause the battery voltage to immediately exceed the Lower limit
voltage 'dn' value and then relay will OFF.But the voltage drops quickly to the
Lower limit voltage 'dn' after Relay OFF and then start to charging.Cycle and
cycle.
At this point you have to reduce the charging current.Usually the charging
current is 10-15% of the battery capacity.For example, if the battery capacity
is 20AH, the charging current is 2-3A.
Note that high current charging can cause the battery to heat up, aging, bulging
or even exploding.
3>.What control method?
Q: This is the voltage control.For example:Lower limit voltage 'dn' is set to
12.0V.Upper limit voltage 'UP' is set to 14.5V.It will close output when the
voltage is charged to 14.5V.Relay will ON and begins to charge when the voltage
is reduced to 12.0V.
4>.Can it be automatically cycled?
Q: Yes,it can.Voltage control mode only controls turn-off and turn-on.
5>.Can it limit the current?
Q: It can't limit current, the charging current is completely dependent on your
charger.
6>.Can I charge a 24V battery by inputting 12V?Or charge a 12V battery by
inputting 48V?
Q: This is a simple voltage controller just for ON/OFF.It can not change output
voltage.So what kind of charger should you prepare for charging the battery!
ماژول کنترل شارژ باتری دیجیتال 6 الی 60 ولت - مدل XY-CD60L
- تولید کننده: China - A
- دسته بندی ها:
- - ماژول تغذیه ، مبدل ولتاژ ، اینورتر و پاور بانک
- کد محصول: RG_110_10F006_000000_14308
- موجودی: 10
-
قیمت پایه : 3,465,000ریال
ارسال رایگان سفارشات بالای 3 میلیون تومان
تعداد بازدید: 756
پرسش و پاسخ مشتریان
برچسب ها: ماژول کنترل شارژ باتری دیجیتال 6 الی 60 ولت - مدل XY-CD60L, RG_110_000000_000000_14308, ماژول تغذیه ، مبدل ولتاژ ، اینورتر و پاور بانک