Product Function:
Set Temperature —- SetT;
Backlash Temperature—–BackT;
1. Heating Mode 'H':
When Temperature ≤ SetT – BackT ;Relay conduction, heating equipment begin to
work;
When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;
2. Refrigeration mode 'C':
When Temperature ≥ SetT + BackT ;Relay conduction, refrigeration equipment begin
to work;
When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;
3. High Temperature Alarm 'ALA':
When Temperature ≥ Alarm Temperature, The system opens the sound and light
alarm, and disconnects the relay, any key stops the sound light;
4. Delay Start ‘OPH':
When a normal heating or refrigeration work is done, the system starts to time
T, and only after the T≥OPH, the system can carry out the next round of heating
or refrigeration work;
5. Temperature Correction Function OFE(-10.0 ~ 10.0°):
The system will work for a long time and may have deviations that can be
corrected by this function, Temperature = Measured + Calibration;
6. Parameter Remote Read/Set:
The parameters such as setting temperature, backlash temperature and temperature
correction can be set through UART.
7. Real-time Temperature Report:
If the temperature reporting function is turned on, the product is transmitted
to the terminal by the UART at 1s intervals, which facilitates data collection;
8. Relay enable (default enable):
If the relay is disable, the relay remains disconnected;
9. Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings;
Working mode setting /backlash temperature :
1. In the running interface, short press SET key, enter the Quick setting
interface;
2. After entering the Quick Setup interface, switch the parameters
3. Through the UP DOWN key, modify the parameter value, support short press/long
press;
4. Long press SET to build more than 3S or continuous 6S without any key
operation, exit quickly set the interface, and save parameters;
Alarm temperature/delay Start /temperature correction:
1. In the operating interface, long press SET more than 3s, enter the parameters
to set the interface;
2. Enter the parameter to set the interface, through the short press SET key to
switch to set the parameters ;
3. through the UP DOWN key, modify the parameter value, support short press/long
press;
4. Long press SET 3s above or continuous 6S without any key operation, exit
parameter set interface, and save parameters;
How to turn on high temperature alarm (default off):
Enter the parameter setting interface, switch to the alarm parameter ALA , turn
on or off the high temperature alarm function by short pressing the STOP button,
and if the high temperature alarm function closes, ALA displays '—-' as a
reminder;
How to turn on delay start (default 0ff):
Enter parameter setting interface, switch to alarm parameter OPH, turn on or off
high temperature alarm function by short Press STOP button, if high temperature
alarm function closes, OPH show '—-' to remind;
Note:
Meaturing temperature range: -50℃ to 110℃
ماژول ترموستات دیجیتال XY-T01 module
- تولید کننده: China - A
- دسته بندی ها:
- - سنسور ، ماژول دما و رطوبت
- کد محصول: NN_201_02C007_000000_12861
- موجودی: 152
-
قیمت پایه : 3,874,063ریال
ارسال رایگان سفارشات بالای 3 میلیون تومان
تعداد بازدید: 9025
پرسش و پاسخ مشتریان
برچسب ها: XYT01, ترمومتر, ترمو متر, دماسنج, دما سنج